Rancang Bangun Acwh Dengan Model Tanki Horizontal Dan Penambahan Pcm Sebagai Isolator Dari Sumber Panas

Irham Rosadi, Chandra Amirsyahputra Siregar, Ahmad Marabdi Siregar, Riadini Wanty Lubis, Fahri Fadillah, Moranelo M

Abstract


Into several stages, namely design, material selection and manufacture. The design uses solidworks 2013 software which includes frame design, tank design, Helical-Coil heat exchanger design and the stage of uniting components designed to be able to flow refrigerant heat to water. The stage of making the tool follows from the design that has been made, namely the frame using angle iron (L) with dimensions of 750mm x 390mm x 1500mm, the tank uses a stainless steel plate and the addition of PCM around the tank with a capacity of 60 liters and an overhaul of the compressor outlet flow that is routed to the Helical-Coil heat exchanger made of copper with a diameter of 6.35mm with APK dimensions 150mm x 300mm or half of the tank height. From the test results, ACWH can work well as evidenced by not using PCM, increasing water temperature with the addition of PCM reaching 60.25 oC within 7 hours of testing, while not using PCM water temperature reaching 60.17 oC within 10 hours.


Keywords


Water heater, Energy wasted, Helical-Coil, Copper, PCM

Full Text:

PDF

References


C A Siregar, A. M. (2021, Maret). Efek Penambahan Pipa Kapiler Bersirip Sebagai Penghantar Panas Tehadap Performance Ac Pada Aplikasi Acwh. Junal.Umsu.Ac.Id.

C A Siregar, A. M. (N.D.). Rancang Bangun Acwh Berkapsitas 60 Liter Memanfaatkan Kapiler Vbersirip Sebagai Pengahantar Panas. Jurnal Mesin (Mesin, Elektro, Sipil,), 2020.

Chandra Amirsyam Putra Siregar, A. M. (N.D.). Studi Eksperimental Pengaruh Efektifitas Acwh Terhadap Panjang Pipa Kapiler Sebangai Penghantar Panas. Jurnal Simetris, 2020.

Ichsani, B. K. (2016). Rancang Bangun Dan Studi Eksperimen Alat Penukar Kalor Panas Untuk Memanfaatkan Energi Refrigerant Keluar Kompresor Ac Sebagai Pemanas Air Pada St/= Dengan Variasi Volume Air. Jurnal Teknik Its.

Iwan Fauzana, A. D. (Juni 2019). Penngunaan Pcm Sebangai Material Penyimpan Kalor Pada Lemari Pendingin. Retrieved From E-Issn 268-321x

Komang Metty Trisna Negara, H. W. (2010, April). Analisa Performansi Sistem Pendingin Ruang Dan Efesiensi Energi Listrik Pada Sistem Water Chiller Dengan Penerapan Metode Colled Energy Storage. Jurnal Ilmiah Teknik Mesin.

S, P. R. (2018).Ranacang Bangun Water Heater Tipe Serpentine Dengan Memanfaatkan Panas Buang Kondensor Ac Split 1 Pk Dengan Kapasitas 120 L. Jurnal Teknik Mesin.

Siregar, C, A, P., Siregar, A, M., Dan Affandi. (2020). Studi Eksperimental Pengaruh Efektifitas Acwh Terhadap Panjang Pipa Kapiler Sebagai Penghantar Panas. Jurnal Simetris, 11(2) E-Issn: 2549-3108.

Siregar, Chandra, A. (2018). Kajian Peleburan Dan Pembukuan Material Berubah Phasa Pada Thermal Sotrage. Talenta Conference Series: Energy And Engineering (Ee) Volume 1 Issue 1 (2018). Issn 2654-7031..

Siregar, C. A., Siregar, A. M., & Setiawan, D. (2021). Efek Penambahan Apk Pipa Kapiler Bersirip Sebagai Penghantar Panas Terhadap Performance Ac Pada Aplikasi Acwh. Jurnal Rekayasa Material, Manufaktur Dan Energi, 4(1), 1-7.

Hendradinata, H., Irawan, F., & Kesuma, A. P. (2018). Rancang Bangun Water Heater Dengan Memanfaatkan Panas Air Conditioning. Petra: Jurnal Teknologi Pendingin Dan Tata Udara, 5(2), 43-49.

King, M. L., & Husin, I. (2018). Eksperimental Kinerja Sistim Refrigerasi Air Conditioner Split Terhadap Parameter Pengujian Dengan Kombinasi Pemanfaatan Dan Pemasangan Water Heater Listrik. Turbulen Jurnal Teknik Mesin, 1(2).




DOI: https://doi.org/10.30596/rmme.v5i2.11722

Refbacks

  • There are currently no refbacks.


Creative Commons License

This work is licensed under a Creative Commons Attribution 3.0 License

Jurnal Rekayasa Material, Manufaktur dan Energi  is abstracting & indexing in the following databases: 

 

Creative Commons License

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

Statcounter View My Stats RMME